Product Details:
Contact Now
Chat Now
|
| Rated Voltage: | 24kV (Um=25kV) | Conductor Size: | 70-120mm² |
|---|---|---|---|
| Number Of Cores: | 3-Core | Insulation Material: | HTV Silicone Rubber |
| Termination Type: | Indoor & Outdoor (Universal) | Cable Type: | XLPE Power Cable |
| Installation Method: | Cold Shrink (No Heat Required) | Operating Temperature: | -60°C To +180°C |
| Creepage Distance: | ≥ 640mm (Heavy Pollution Class) | Impulse Withstand Voltage: | 125kV Peak |
| UV Resistance: | Excellent (ASTM G154 Tested) | Ingress Protection: | IP68 |
| Standards Compliance: | IEC 60502-4, IEEE 48 | ||
| Highlight: | 24kV Cold Shrink Termination Kit,Anti-UV Waterproof Cable Termination,SE Asia Power Cable Accessories |
||
The WNRLN CST-24/3C-120-IO is a universal 24kV cold shrink termination kit engineered for 3-core XLPE insulated power cables with conductor sizes 70-120mm². Specifically designed and field-proven across Southeast Asia's power projects, this termination kit thrives in the region's most demanding environmental conditions – tropical high-humidity, coastal salt-spray corrosion, and monsoon heavy-rain exposure. With HTV silicone rubber insulation, integrated stress control, and IP68 waterproof sealing, it delivers reliable, maintenance-free performance for indoor substations and outdoor pole-mounted installations alike.
| Rated Voltage (U0/U) | 12/20kV (24kV class, Um=25kV) |
| Conductor Size Range | 70mm² – 120mm² |
| Number of Cores | 3-Core |
| Insulation Material | HTV Silicone Rubber (Anti-UV Grade) |
| Termination Type | Indoor & Outdoor (Universal) |
| Cable Insulation Type | XLPE (Cross-Linked Polyethylene) |
| Installation Method | Cold Shrink – Pull-out Core, No Heat Required |
| Operating Temperature | -60°C to +180°C (Continuous) |
| Creepage Distance | ≥ 640mm (IEC 60815 Heavy Pollution Class III) |
| Impulse Withstand Voltage | 125kV Peak (1.2/50μs waveform) |
| Power Frequency Withstand | 55kV / 5 minutes (Dry & Wet) |
| Partial Discharge | <5pC at 1.73U0 (20.7kV) |
| UV Resistance | ASTM G154 Cycle 1, 5000 hours – No degradation |
| Salt Fog Resistance | IEC 60068-2-52 Severity 4 (Marine/Coastal) |
| Ingress Protection | IP68 (Submersion to 3m / 72 hours) |
| Standards Compliance | IEC 60502-4, IEEE 48, IEC 60815 |
Every WNRLN termination kit undergoes 100% routine testing including partial discharge measurement (<5pC at 1.73U0), AC voltage withstand (55kV/5min dry and wet), and dimensional inspection. Our ISO 9001:2015 certified facility maintains rigorous batch traceability. Full type test reports per IEC 60502-4 – including thermal cycling, impulse voltage, and salt fog aging – are available to utility and EPC buyers specifying equipment for Southeast Asian power projects.
Contact our sales team today for project pricing, type test documentation, or OEM requirements. We support Southeast Asian utility tenders with complete technical submissions and factory acceptance testing (FAT) arrangements.
Contact Person: Mr. Richard Lee
Tel: +8618627678155